Installation, Locating your gas fireplace, Manufactured mobile home additional requirements – Regency Panorama P36D User Manual

Page 9

Advertising
background image

FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

9

INSTALLATION

Diagram 1

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 30,000 Btu/h)
after burning appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

LOCATING YOUR

GAS FIREPLACE

1) When selecting a location for your fi replace,

ensure that the clearances outlined on this
page are met.

2) Provide adequate clearances for

servicing.

3) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.

4) The P36D-1 Direct Vent Gas Fireplace

can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.

5) This appliance is Listed for bedroom

installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) The P36D-1 Direct Vent Gas Fireplace is

approved for alcove installations, which meet
the clearances listed on the next page.

7) We recommend that you plan your installation

on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.

Note: For vent terminations see "Exterior

Vent Termination Location" section.

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

HEATWAVE

DUCT SYSTEM

(OPTIONAL)

#946-556

The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.

Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.

HEAT RELEASE KIT

(OPTIONAL)

#946-570

The Heat Release Kit expels warm air from
the fi replace to the outside of the building,
allowing the fi replace to be operated with less
heat entering the room. The kit may be used
on either the left or right side.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1) Ensure that structural members are not cut

or weakened during installation.

2) Ensure proper grounding using the #8

ground lug provided. See "Wiring Diagram"
section.

Advertising