Regency™ series options, The kensington, Front installation – Regency Panorama P36D User Manual

Page 60

Advertising
background image

FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

60

REGENCY™ SERIES OPTIONS

THE KENSINGTON

®

FRONT INSTALLATION

1) Bend tabs downwards located at the back of The Kensington

®

Front.

Bend tabs
downwards.

Backside of front shown.

2) Secure the bottom frame of the Front by loosening the inner screw

on the hinge brackets on both the left and right side of the fi rebox.
Slide frame in place and secure.

Left Side Shown

Hinge bracket on

bottom of fi rebox

3) Slide tabs into louver brackets located on the inside top of the

fi rebox.

Bracket inside
top of fi rebox.

Kensington Front

frame

4) Remove existing control switch box from under fi rebox by disconnecting

wires connected to the valve at TH-TH/TP terminals and discard.

Wires connected to Valve.

Control Box

5) Connect the ON/OFF switch wires coming from the left side of the

Front to the valve, with black hooked up to the TH/TP terminal and
red hooked up to the TH terminal.

NOTE: If fan option is not used please see step (5) of optional fan
installation for placement of fan control box.

Valve

ON/OFF Switch

Wires

Fan Control Box

Tabs

6) For optional fan installation, see "Optional Fan Installation"

section.

7) For 2-panel & 3-panel door installation, see "2-Panel Door

Installation & 3-Panel Door Installation" sections.