Regency™ series options, The kensington, Balmoral front – Regency Panorama P36D User Manual

Page 62

Advertising
background image

FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

62

THE KENSINGTON

®

& BALMORAL FRONT

2-PANEL DOOR INSTALLATION

3-PANEL DOOR INSTALLATION

REGENCY™ SERIES OPTIONS

2) Mount 3-panel door frame to fl ange on sub-frame, ensuring to line-up

holes. Secure using the 4 screws provided.

Secure bottom of

sub-frame with

screws.

1) Install sub-frame by hooking top over glass door, push in bottom of

frame and secure with 2 screws.

Sub-Frame

Secure bottom of

sub-frame with

screws.

1) Install sub-frame by hooking top over glass door, push in bottom of

frame and secure with 2 screws.

Sub-Frame

2) Mount 2-panel door frame to fl ange on sub-frame, ensuring to line

up holes. Secure using the 6 screws provided.

3) Hook left side door to door frame by placing the door hinges (top &

bottom) over pins on door frame. Repeat for right side door.

Note: It will be easier to put the door in place by starting with the
bottom hinge.

Left Side Door

Pin on door frame

Note: If you fi nd that the left or right side door is lower then the other,
use the spacer provided to help align the doors.


The spacer is to be placed over the bottom pin before installing the
screen door.