M30880T-EPB User’s Manual

2. Setup

REJ10J0497-0100Z Rev.1.00 January 16, 2005

Page 30 of 100


2.9.1 Connecting to a 100-pin LCC Socket
When connecting the emulation probe to a 100-pin LCC socket (Yamaichi Electronics Co., Ltd.: IC61-1004-051 etc.) on the
user system, following the procedure below.

(1) Attach the CN2 side of the M30880T-EPB to the CN2 side of the M30800T-PTC.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.

100-pin LCC socket

M3T-FLX160-EPB

M30880T-EPB

CN2 side

(1)

No. 1 pin

(2)

M30800T-PTC

User system

Figure 2.8 Connecting to a 100-pin LCC socket

CAUTION

Notes on Connecting the User System:

Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.

The small connectors of the M30880T-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.

For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.
http://www.yamaichi.co.jp/e/index.shtml