2 selecting clock supply, Important – Renesas Emulation Probe for M32C/88 Group M30880T-EPB User Manual

Page 42

Advertising
background image

M30880T-EPB User’s Manual

2. Setup

REJ10J0497-0100Z Rev.1.00 January 16, 2005

Page 42 of 100


2.10.2 Selecting Clock Supply
With this product, a clock supply can be set in Init dialog box of Emulator tab of the emulator debugger. Table 2.4 lists the
factory-settings of each clock supply.

Table 2.4 Clock supply to the MCU and default settings

Clock

Display of emulator debugger

Description

Default setting

Internal

Internal oscillator circuit

(OSC-3 or OSC-2)

Yes

External

Oscillator of user system

-

Main X

IN

-X

OUT

Generated

Internal generator circuit

(1.0 to 32.0 MHz)

-

Internal

Internal oscillator circuit

(32.768 kHz)

-

Sub X

CIN

-X

COUT

External

Oscillator of user system

Yes


IMPORTANT

Notes on Changing the Clock Supply:

The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting CLK
command on the script window.

For X

CIN

-X

COUT

, it is necessary to set switches in the emulator. For details, refer to "2.10.1 Setting Switches of

Emulation Probe" (page 38).


(1) Using an Internal Oscillator Circuit Board

1) Kinds of Oscillator Circuit Boards

The PC7501 comes with an oscillator circuit board OSC-3 (30 MHz). And an oscillator circuit board OSC-3 (32 MHz)
and an oscillator circuit board OSC-2 (bare board) are included with this product. If you use the internal oscillator
circuit board OSC-3 (32 MHz) or OSC-2 of the PC7501 as a main clock, choose "Internal" in the emulator debugger
after replacing oscillator circuit boards to change a clock supplied to an MCU.

Advertising