Caution – Renesas Emulation Probe for M32C/88 Group M30880T-EPB User Manual

Page 32

Advertising
background image

M30880T-EPB User’s Manual

2. Setup

REJ10J0497-0100Z Rev.1.00 January 16, 2005

Page 32 of 100


2.9.3 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 2)
Figure 2.10 shows how to connect the emulation probe to a 100-pin 0.65-mm-pitch foot pattern on the user system with the
M3T-DIRECT100S (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-
DIRECT100S, refer to each user's manual.

(1) Attach the M3T-DIRECT100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the M30800T-PTC to the M30880T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

M3T-100LCC-DMS

(not included)

M3T-FLX160-EPB

M30880T-EPB

CN2 side

(3)

(4)

M30800T-PTC

(2)

(1)

100-pin 0.65-mm-pitch

(100P6S) foot pattern

No. 1 pin

User system

M3T-DIRECT100S

(not included)

Figure 2.10 Connecting to a 100-pin 0.65-mm-pitch foot pattern (2/3)

CAUTION

Notes on Connecting the User System:

Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.

The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20
insertion/removal iterations.

The small connectors of the M30880T-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.