2.9.7 Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 3)
Figure 2.14 shows how to connect the emulation probe to a 100-pin 0.5-mm-pitch foot pattern on the user system with the
M3T-F160-100NSD (not included), and here following is its procedure. For details on the M3T-F160-100NSD, refer to its
user's manual.

(1) Mount the NQPACK100SD included with the M3T-F160-100NSD to the user system.
(2) Attach the YQPACK100SD included with the M3T-F160-100NSD to the NQPACK100SD.
(3) Insert the YQ-GUIDE's included with the YQPACK100SD to the YQPACK100SD.
(4) Attach the M3T-F160-100NSD to the YQPACK100SD.
(5) Attach the M30880T-EPB to the M3T-F160-100NSD.

*

M3T-FLX160-EPB

M30880T-EPB

CN2 side

(5)

(1)

100-pin 0.5-mm-pitch

(100P6Q) foot pattern

No. 1 pin

User system

M3T-F160-100NSD

(not included)

FLASH MCU etc.

On-board evalution

*: These four items are available in one package.

YQPACK100SD

NQPACK100SD

HQPACK100SD

(not included)

(2)

(3)

(4)

YQ-GUIDE (x4)

These corners are not round.

Figure 2.14 Connecting to a 100-pin 0.5-mm-pitch foot pattern (3/3)

CAUTION

Notes on Connecting the User System:

Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator.

The small connectors of the M30880T-EPB and M3T-F160-100NSD are guaranteed for only 50
insertion/removal iterations.