5 notes on using this product, Important – Renesas Emulation Probe for M32C/88 Group M30880T-EPB User Manual

Page 86

Advertising
background image

M30880T-EPB User’s Manual

4. Hardware Specifications

REJ10J0497-0100Z Rev.1.00 January 16, 2005

Page 86 of 100

4.5 Notes on Using This Product

Notes on using this product are listed below. Be sure to read these notes before using this product.

IMPORTANT

Notes on Downloading Firmware:

Before using this product for the first time, it is necessary to download the dedicated firmware (control software
built into the PC7501). Please note that, to do this, it is necessary to start up the PC7501 in maintenance mode.
For firmware download procedures, see "2.7 Downloading Firmware" (page 26). Once the firmware has been
downloaded, the product can be used by simply turning on the power.

Do not shut off the power while downloading the firmware. If this happens, the product will not start up
properly. If power is shut off unexpectedly, redownload the firmware.

Except when a target status error occurs, if the self-check is not completed successfully, there may be trouble
with the product. In such case, contact your sales representative.

Perform the self-check while not connecting the user system.

Note on Quitting the Emulator Debugger:

To restart the emulator debugger after it ends, always shut power to the emulator module off once and then on
again.

Notes on Power Supply to the User System:

Pin Vcc of the emulator is connected to the user system to observe the voltage of the user system. Therefore
design your system so that the user system is powered separately.

The voltage of the user system should be within the following.

4.2

V

≤ VCC1 = VCC2 ≤ 5.5 V

Do not change the voltage of the user system after turning on the power.