MIDI Implementation

Using Roland’s one-way System Exclusive message you can transfer
data between FC-300 and another device.

You can use the following Model ID for the FC-300.

• 00H 00H 1EH (FC-300)

You can use System Exclusive messages to transmit and receive
the FC-300’s internal parameters in the form of bulk data.

• 00H 00H 20H (Foot Controller)

You can use System Exclusive messages to transmit and receive
the FC-300’s operational messages and display messages.

The Device ID can be set within the 00H to 1FH range.

For more on setting the Device ID, see

“Setting the Device ID”

(p.

52).

Request Data 1 RQ1 (11H)

DATA SET 1 DT1 (12H)

There are two type of the FC-300 System Exclusive message. FC-300
can send and receive the operation of this unit and display
information by using the system exclusive message.

Address Block Map

Mode Status (Individual area)

*1 Outputs on power-up or when Mode change is made.

Also outputs upon receiving Data Request (RQ1).
Data Set (DT1) is ignored.

*2 Mode Status is changed when Data Set (DT1) is received.

Changes the System Exclusive Mode when On is received.
MODE pedal is pressed same operation when Off is received in
System Exclusive Mode.

*3 Changes the display of LCD in System Exclusive Mode when

Data Set (DT1) is received.
Appears the received data in Message Display Status Address
when PLAY is received.
Appears the TUNER screen and received data in Tuner Pitch
Status Address when TUNER is received. (FC-300 has not
TUNER function.)
Outputs when Data Request (RQ1) is received.

3. Exclusive Communications

Byte

Description

F0H

System Exclusive Status

41H

Manufacturer ID (Roland)

dev

Device ID (dev: 00H-0FH)

mdl

Model ID
(mdl: 00H 00H 1EH) FC-300
(mdl: 00H 00H 20H) Foot Controller

11H

Command ID (RQ1)

aaH

Address MSB

bbH

Address LSB

ssH

Size MSB

ttH

Size LSB

sum

Checksum

F7H

EOX (End of System Exclusive)

Byte

Description

F0H

System Exclusive Status

41H

Manufacturer ID (Roland)

dev

Device ID (dev: 00H-0FH)

mdl

Model ID
(mdl: 00H 00H 1EH) FC-300
(mdl: 00H 00H 20H) Foot Controller

12H

Command ID (DT1)

aaH

Address MSB

bbH

Address LSB

ddH

Data

:

:

eeH

Data

sum

Checksum

F7H

EOX (End of System Exclusive)

4. Parameter Address Map
(Model ID = 00H 00H 20H)

Address (H)

Block

Description

10 00

Mode Status

Read/Write

20 00

Pedal Status

Read

30 00

Pedal LED Status

Write

40 00

BANK/NUMBER Display Status

Write

50 00

Controller Status

Read/Write

60 00

Message Display Status

Write

68 00

Message Display User Font

Write

70 00

Tuner Display Status

Write

71 00

Tuner Pitch Status

Write

Address (H)

Size (H)

Data (H)

Parameter

Description

10 00

00 01

00-01

SYSEX Mode
Status *1

0: Off, 1:On

10 01

00 01

00-01

SYSEX Mode
Status *2

0: Off, 1:On

10 02

00 01

00-01

Function
Mode Status *3

0: Play, 1:TUNER