Oki B4100 User Manual
Page 191
Advertising
![background image](/manuals/203797/191/background.png)
40055101TH Rev.4
191 /
b)
Remove the Sub-roller from the
Scanner Frame.
c)
Remove the spring 1 from the
Scanner Frame.
d)
Remove the ADF Roller Assem-
bly by removing the gear on the
Scanner Frame.
e)
After removing the ADF Roller,
remove the Pinch Roller by hold-
ing up the two springs 2 while the
Pinch Roller Shaft is pushed and
released.
f)
Remove the Contact Image Sen-
sor by disconnecting the connec-
tor.
5)
PC1, PC2
a)
After disconnecting the two con-
nectors, remove the photo-coupler
sensors PC1 and PC2 on the Bot-
tom Plate by pressing the latch
using the flat screwdriver or the
like.
(2)
Reassembly procedure
Reverse the disassembly procedure.
PC2
PC1
(FX-050VP-C4-017)
(FX-050VP-C4-016)
Spring 1
Spring 2
ADF Roller
Assembly
Sub-roller
Gear
Pinch Roller
Contact Image
Sensor
Advertising