40055101TH Rev.4

202 /

5.3.1 OKIFAX 5000 Series Confirmation Items

The clock frequency and power voltage of the machine are not possible to adjust in the field.
However, their measurement procedures are described here for confirmation of clock frequency and each
voltage.

1)

Clock Frequency

Measurement point:

M17 board; LC2-3 pin and ground terminal

Specification:

20.000 MHz

±

50 PPM

Note:

If the counter does not read with 20.000 MHz, replace with a new crystal oscillator (X1).

2)

+5V DC Voltage (SUB)

Measurement point:

M17 board; CN16-1 pin and ground terminal

Specification:

+5V

±

4% (+4.5V to 5.2V)

3)

+5V DC Voltage

Measurement point:

M17 board; CN1-B12/A13/B13 pin and ground terminal

Specification:

+5V

±

4% (+4.5V to 5.2V)

4)

+8V DC Voltage

Measurement point:

M17 board; CN1-A14 pin and ground terminal

Specification:

+6.5V to 15V

5)

–8V DC Voltage

Measurement point:

M17 board; CN1-B14 pin and ground terminal

Specification:

–15V to –6.5V

6)

+30V DC Voltage

Measurement point:

M17 board; CN1-A15/B15 pin and ground terminal

Specification:

+24V to +45V

7)

Contact Image Sensor Output (SIG signal)

Measurement point:

M17 board; CN10-1 pin and ground terminal

Specification:

A waveform sample is shown below.

Test chart:

White sheet (A4 size)

1.0Vp-p

2.5ms