Oki B4100 User Manual

Page 200

Advertising
background image

40055101TH Rev.4

200 /

5.2.1 OKIOFFICE44/OKIFAX 4100 Confirmation Items

The clock frequency and power voltage of the machine are not possible to adjust in the field.
However, their measurement procedures are described here for confirmation of clock frequency and each
voltage.

1)

Clock Frequency

Measurement point:

R44 board; LC2-3 pin and ground terminal

Specification:

20.000 MHz

±

50 PPM

Note:

If the counter does not read with 20.000 MHz, replace with a new crystal oscillator (X1).

2)

+5V DC Voltage (SUB)

Measurement point:

R44 board; CN7-12 pin and ground terminal

Specification:

+5V

±

4% (+4.5V to 5.2V)

3)

+5V DC Voltage

Measurement point:

R44 board; CN7-1, 2 & 3 pin and ground terminal

Specification:

+5V

±

4% (+4.5V to 5.2V)

4)

–8V DC Voltage

Measurement point:

R44 board; CN7-9 pin and ground terminal

Specification:

–15V to –6.5V

5)

+30V DC Voltage

Measurement point:

R44 board; CN7-8 pin and ground terminal

Specification:

+24V to +45V

6)

Contact Image Sensor Output (SIG signal)

Measurement point:

R44 board; CN5-1 pin and ground terminal

Specification:

A waveform sample is shown below.

Test chart:

White sheet (A4 size)

2.0Vp-p

5ms