40055101TH Rev.4

519 /

Caution: The toner sensor is not monitored when the drum is inactive.

(a) When the toner-low state continues twice, Toner Low occurs. (This state is monitored at a cycle

of 40 milliseconds.)

(b) When the toner-full state continues twice, Toner Low is released. (This state is monitored at a cycle

of 40 milliseconds.)

(c) When the toner sensor does not change over two cycles (T x 2), the toner sensor alarm state occurs.

(d) After the EP unit has been replaced (after the drum counter has been reset), Toner Low is not

detected when the drum counter indicates 1 to 100 counts.

Image drum unit

Agitation bar (iron)

Magnet

Toner sensor lever

Photointerrupter

Hardware Configuration of Toner Sensor

• Toner detection method

(1) Toner sensor monitoring conditions are shown in the figure below.

B1.4

Toner Low Detection

• Hardware configuration of toner sensor

The figure below shows the hardware configuration of the toner sensor.

t1

T

Magnet draw-in

Toner sensor