Castile Pellet Stove

RR

Correct Flame Size, Yellow/White in Color

Correct

Figure 30.3

Tall, Lazy Flame, Orange in Color

Incorrect

Figure 30.1

Figure 30.2

C. High Ash Fuel Content Maintenance

• Frequency: As needed

• By: Homeowner

• Task:

Poor quality pellet fuel, or lack of maintenance, can create

conditions that make the firepot fill quickly with ashes and

clinkers. This condition makes the appliance suscepti-

ble to overfilling the firepot with pellets which may result

in smoking, sooting and possible hopper fires.

Figure

30.1 shows an example where the firepot overfills, pel-

lets back up into the feed tube and ash has accumulated

in the firebox.

Figure 30.2 illustrates an inefficient and

non-economical method of burning fuel caused by poor

quality pellet fuel.

Figure 30.3 shows the correct flame

size when good quality, premium pellet fuel is burned.
If the ash buildup exceeds the half way point in the

firepot

IMMEDIATE ATTENTION AND CLEANING IS

REQUIRED. Follow the proper shutdown procedure

below and the detailed instructions found in this sec-

tion for each step listed below.
• Pull the heat exchanger cleaning rods.

Section 10.7

• Empty the firepot.

Section 10.2

• Clean the firebox.

Section 10.4

• Empty the ash drawer.

Section 10.3

• Dispose of the ashes.

Section 10.6

• Restart the appliance with premium grade fuel.

Shock and Smoke Hazard
• Turn down thermostat, let appliance completely

cool and exhaust blower must be off. Now you

can unplug appliance before servicing.

• Smoke spillage into room can occur if appliance

is not cool before unplugging.

• Risk of shock if appliance not unplugged before

servicing appliance.

CAUTION

Proper Shutdown Procedure