Page 8

250-6422D

October 11, 2005

R

Castile Pellet Stove

RR

Straight Back Against

Wall

Inches Millimeters

A

Back Wall to Appliance

2

51

B

Side Wall to Appliance

6

152

Corner Installation

Inches Millimeters

C

Walls to Appliance

2

51

Vertical Installation

Inches Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Cast Top

6

152

F

Back Wall to Appliance

8

203

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

Corner Installation

Inches Millimeters

G

Walls to Appliance

2

51

H

Side Wall to Flue Pipe

3

76

Alcove Installation

Inches Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

38

965

Maximum Alcove Depth

36

914

Dimension to Corner

Inches Millimeters

I

Flue Center Line

10-3/8

264

J

Back of Top Vent Adapter

9-1/8

232

B. Clearances to Combustibles (UL and ULC)

Fire Risk.
Comply with all minimum clearances to

combustibles as specified.