Reference materials – Quadra-Fire CASTILE-CCR User Manual

Page 34

Advertising
background image

Page 34

250-6422D

October 11, 2005

R

Castile Pellet Stove

RR

11

Reference Materials

7. Heat Exchangers
The heat exchangers transfer hot air from the exhaust system

into convecton air. Remove the stainless steel top baffle to

access the heat exchangers. There are 2 clean out rods

located under the heat exchangers.
8. Heat Output Switch
The heat output switch is located on the upper right rear

corner. The funtion of the heat ouput switch is to regulate

the burn rates; low, medium and high settings.
9. Igniter
The igniter is mounted on the base of the firepot. Combustion

air travels over the red hot igniter creating super heated air

that ignites the pellets.
10. Junction Box And Wiring Harness
The junction box is located on the right side of the appliance,

behind the right side panel. The junction box and wiring

harness are replaced as one component.
11. Power Supply
The power outlet is located on the lower right rear corner.

Check the wall receptacle for 120 volt, 60 Hz (standard

current). Make sure the outlet is grounded and has the correct

polarity. A good surge protector is recommended.
12. Red Call Light
The red call light is on the front of the junction box, behind

the control box. The function of the red call light is to indicate

that the thermostat is calling for heat.
13. Reset Button
The reset button is located on the back of the appliance on

the upper right corner of the side panel under the heat output

control switch. The function of the button is to momentarily

open the thermostat circuit, which restarts the system.
14. Thermocouple
The thermocouple is located on top of the firepot inside

the thermocouple cover (ceramic protection tube). The

thermocouple sends a millivolt signal to the control box

indicating the preset temperatures of the green and red lights

have been obtained.
15. Thermostat
The appliance is designed to run on a 12 volt AC thermostat.

The heat anticipator should be set on the lowest setting

available.

When describing the location of a component,

it is always AS YOU FACE THE FRONT OF

THE APPLIANCE.

2. Convection Blower
The convection blower is mounted at the bottom rear of the

appliance. There are 2 impellers, one on each side of the

motor. The convection blower pushes heated air through the

heat exchange system into the room.
3. Exhaust Blower
The exhaust blower is located on the right side of appliance.

The exhaust blower is designed to pull the exhaust from the

appliance and push it out through the venting system.
4. Feed System
The feed system is located on the right side of the appliance

and can be removed as an entire assembly. The assembly

includes the feed motor, mounting bracket, bearing and feed

spring (auger). The hollow feed spring (auger) pulls pellets

up the feed tube from the hopper area and drops them down

the feed chute into the firepot.
5. Firepot
The firepot is made of high quality ductile iron and has a

cleaning pull-out rod. The floor of the firepot opens for

cleaning when you pull out the rod. Be sure that the floor

returns to a completely closed position or your appliance will

not operate properly.
6. Fuse
The fuse is located on the front of the junction box on the

right side of appliance. The fuse will blow should a short

occur and shut off power to the appliance.

NOTE:

Do

NOT open the control box.

This will void the

warranty. FolIow proper shutdown procedures first if

you need to plug in or remove the control box.

1. Control Box
a. The control box is located on lower left side of

appliance, behind the left side panel and above the

vacuum switch.

b. There is a light located inside of the control box. The

internal light will turn green when the appliance has

reached a temperature of 175

ο

F (79°C) in the firepot.

and will turn red when it reaches 600

o

F (315°C).

c. There is also an internal blue light located in the upper

left corner of the control box. When you plug in the

appliance the blue light will automatically start blinking

6 times in a row for 60 seconds and then will stop.

A. Component Function