Quadra-Fire CASTILE-CCR User Manual

Page 9

Advertising
background image

RR

R

October 11,, 2005

250-6422D

Page 9

Castile Pellet Stove

*L Exception for Horizontal Installations:
USA INSTALLATIONS
: A noncombustible floor protection is

recommended extending beneath the flue pipe when installed

with horizontal venting or under the Top Vent Adapter with

vertical installation.
CANADA INSTALLATIONS: A noncombustible floor pro-

tection extending beneath the flue pipe is

required with hori-

zontal venting or under the Top Vent Adapter with vertical

installation.

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)

C. Hearth Pad Requirements (UL and ULC)

Use a noncombustible floor protector, extending beneath

appliance and to the front, sides and rear as indicated.

Measure front distance “M” from the surface of the glass

door.

Hearth Pad Requirements

Inches Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152