Castile pellet stove – Quadra-Fire CASTILE-CCR User Manual

Page 35

Advertising
background image

RR

R

October 11,, 2005

250-6422D

Page 35

Castile Pellet Stove

16. Snap Disc #1 (Convection Blower) 125°F
Snap disc #1 is located on the right side of the appliance on

the top of the heat exchanger box. There are 2 purple wires

connected to it. This snap disc turns the convection blower on

and off as needed. Power is always present at snap disc #1.
17. Snap Disc #2 (Thermostat Override) 175t°F
Snap disc #2 is also located on the right side of the appliance

below snap disc #1 and has a red reset button. There are 2

orange wires connected to it. This snap disc will turn off the

feed system, which will turn off the appliance if an overfire

condition should occur or if the convection blower should fail

to operate.
18. Snap Disc #3 (Back Burn Protector) 250°F
Snap disc #3 is mounted on the back of the auger tube in

the center of the appliance and has a red reset button. To

access it remove the right side panel. If the fire tries to burn

back into the feed system or push exhaust up the feed tube,

this snap disc will shut the entire system off. This disc must

be manually reset.
19. Vacuum Switch
The vacuum switch is located on the right side of the

appliance behind right side panel. This switch turns the

feed system on when vacuum is present in the firebox. The

vacuum switch is a safety device to shut off the feed motor if

the exhaust or the heat exchanger system is dirty or plugged

or if the firebox door is open.
20. Wiring Harness
See Figure 35.1 below.

Figure 35t.1

VACUUM

SWITCH

SNAP

DISC #2

CAPACITOR

FEED

MOTOR

SNAP

DISC #1

CONVECTION

BLOWER

COMBUSTION

BLOWER

SNAP

DISC #3

FUSE

MALE

FEMALE

RESET

BUTTON

CALL

LIGHT

THERMOS TAT

BLOCK

HEAT OUTPUT

SWITCH

THERMOCOUPLE

IGNITOR

YELLOW

YELLOW

RED

RED

ORANGE

WHITE

BLUE

BLUE

PURPLE
GRAY

BLACK

BLACK

BLACK

BLACK

YELLOW

YELLOW

GR

AY

WHITE

BLUE

Advertising
This manual is related to the following products: