Request sense command (03h) (continued) – Quantum 10K II User Manual

Page 248

Advertising
background image

SCSI Description

Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives

5–181

REQUEST SENSE Command (03h) (continued)

Table 5–86 Supported Additional Sense Codes and Sense Code Qualifiers (in Hex)

(continued)

Sense Key

Sense

Code

Sense

Qualifier

Meaning

02h NOT READY (continued)

04

83

Error Reading Diskware File

04

84

Diskware Not Loaded Yet – Issue Start

CMD

04

85

Code Jumped to Dead Vector

04

86

Drive Not Ready, Configuration Page

8/HDA Mismatched

04

88

Error Reading Config Page File

04

91

Drive Not Ready, Self Scan is Running

19

00

Defect List in Error

19

01

Drive Not Ready, Unknown Defect List

19

03

Defect List Error in Grown List

31

00

Drive Not Ready, Format Corrupted

31

01

FORMAT UNIT Command Failed

40

80

Diagnostics Failure, Unknown Reason

40

81

Diagnostics Failure, RAM Failure

40

82

Diagnostics Failure, Inconsistent Data

40

83

Diagnostics Failure, HDA Diagnostic

40

84

Diagnostics Failure, PCB Diagnostic

40

85

Error Detection Code (EDC) Error

40

86

DMA Overrun Error

40

99

ROM and Resident Code are Incompatible

03h MEDIA ERROR

02

00

No Seek Complete

03

01

Pre-Amp Write Unsafe

03

84

Diag: Write Fault

0C

00

Write Error

0C

02

Write Error, Auto Reallocation Failed

0C

03

Write Error, Recommend Reassignment

11

00

Unrecovered Read Error

11

04

Unrecovered Read Error, Auto

Reallocation Failed

11

0B

Unrecovered Read Error, Recommend

Reassignment

11

81

System File Has Checksum Error

11

84

Error Reading Diskware Vector Table File

(continued)

Advertising