3 spin up for sca-2 connector versions – Quantum 10K II User Manual

Page 40

Advertising
background image

Installation

Quantum Atlas 10K II Ultra 160/m SCSI Hard Disk Drives

3

13

Figure 3–5 Pin Locations on SCA-2 Connector

Table 3–3 SCSI ID Pin Assignments (SCA-2 Connector Versions of the Disk Drive)

3.4.2.3 Spin Up for SCA-2 Connector Versions

Atlas 10K II drives with SCA-2 SCSI connectors have three Spin Up modes:
Option 1

Spin up occurs immediately when power is applied.

Option 2

Drive spin up occurs after a predetermined delay following power on.
Set the delay parameters with the MODE SELECT Command,
Quantum-Unique Page (39h).The delay is equal to a user-specified
multiplier multiplied by the numerical SCSI ID of the drive. This
will give a staggered spin-up in multiple-drive installations.

Option 3

Drive spin up is controlled by the START STOP UNIT command.

Configure the desired spin up option (Table 3-4) by setting the state of the
DELAY_SPIN (Pin 38) and STAGGER_SPIN (Pin 78) inputs on the 80-pin SCA-2
connector (Figure 3-5). The states of these signals are set by using either hard-wired
connections at the backplane or backplane logic.

Pin 40 Pin 39

Pin 80 Pin 79

HDA

Location on SCA Connector

SCSI ID

ID3 - Pin 80

ID2 - Pin 40

ID1 - Pin 79

ID0 - Pin 39

0

0

0

0

0

1

0

0

0

1

2

0

0

1

0

3

0

0

1

1

4

0

1

0

0

5

0

1

0

1

6

0

1

1

0

7

0

1

1

1

8

1

0

0

0

9

1

0

0

1

10

1

0

1

0

11

1

0

1

1

12

1

1

0

0

13

1

1

0

1

14

1

1

1

0

15

1

1

1

1

0 = Open Circuit, +2.4 V to Vcc +0.5 V
1 = Ground, -0.5 V to +0.4 V

Pin 2 Pin 1

Pin 42 Pin 41

Advertising