SCSI Description

Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives

5–187

REQUEST SENSE Command (03h) (continued)

Table 5–86 Supported Additional Sense Codes and Sense Code Qualifiers (continued)

Sense Key

Code

Qualifier

Meaning

06h UNIT ATTENTION

(continued)

29

03

Bus Device Reset Occurred

29

04

Device Reset Occurred, Bugcheck

Occurred

29

05

Bus Mode Changed to Single-Ended

29

06

Bus Mode Changed to LVDS

29

86

Commands Aborted, ACK Overrun

Detected

2A

01

Mode Parameters Changed

2A

02

Log Parameters Changed

2A

03

Persistent Reservations Were Cleared

2F

00

Commands Aborted by Another Initiator

3F

01

Target Operating Condition Changed,

Microcode has Changed

5C

01

Spindle Sync’d

5C

02

Spindle Not Sync’d

5D

00

SMART Tripped

5D

01

TA Error Rate Threshold Exceeded

5D

02

READ or WRITE Error Rate Thresh. Exceeded

5D

0B

SMART Triggered Due to Spin Retry

5D

FF

SMART Test Trip

07h DATA PROTECT

27

00

Unit Hardware or Firmware Write

Protected

09h VENDOR UNIQUE

81

00

Read Overlaps Deferred Write

0Bh ABORTED COMMAND

00

00

No Additional Sense Information Error

25

00

Logical Unit Not Supported

41

00

Data Path Failure

41

86

Commands Aborted, ACK Overrun

Detected*

43

00

Message Reject Error

44

00

Busy Timeout

45

00

Selection or Reselection Failure

47

00

SCSI Bus Parity Error Detected

48

00

Initiator Detected Error (IDE) Message

Received

48

86

ACK Overrun Detected Error

49

00

Invalid Message Error

4E

00

Overlapped Commands Attempted

0Eh MISCOMPARE

1E

00

No Additional Information

Advertising