Venting systems, Warning caution – Quadra-Fire PELLET INSERT CB1200MI-MBK User Manual

Page 15

Advertising
background image

R

R

R

February 3, 2010

7014-188B

Page 15

CB1200-I Pellet Insert

5

Venting Systems

NOTE:
In Canada, where passage through a wall or partition of

combustible construction is desired, the installation shall

conform to CAN/CSA-B365.

Figure 15.1

Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211

Factory-built chimney must be a minimum 6 inch

(152mm) UL103 HT.

WARNING

CAUTION

Never draw outside combustion air from:

• Wall, floor or ceiling cavity

• Enclosed space such as an attic or garage

NOTE:

Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design

preference.

A.

Full Reline With Outside Air - Horizontal

Outside Air through Rear

Wall (Horizontal)

NOTE; Use metal plate around

exhaust vent pipe and seal all

edges with non-flammable insu-

lation such as fiberglass, mineral

wool or ceramic.

Do not use high temperature

caulking materials to seal any

edge to prevent furture service-

ability.

Figure 15.1