Troubleshooting (cont’d) – Quadra-Fire PELLET INSERT CB1200MI-MBK User Manual

Page 32

Advertising
background image

Page 32

7014-188B

February 3, 2010

R

CB1200-I Pellet Insert

R

R

Symptom

Possible Cause

Corrective Action

Convection blower fails to

start.

No call light.

#1 snap disc defective.

Blower not plugged in.

Blower is defective.

Control box is defective.

Defective control box.

Replace snap disc.

Check that blower is plugged into wire har-

ness.

Replace blower.

Replace control box.

Exhaust blower fails to

start or does not shut off.

Blower not plugged in.

Blower is clogged with ash.

Blower is defective.

Control box is defective.

Check that blower is plugged into wire har-

ness.

Clean exhaust system.

Replace blower.

Replace control box.

Large, lazy flame, orange

color. Black ash on glass.

Dirty appliance.

Poor fuel quality, high ash content.

Firepot clean-out plate not completely

closed.

Excessive amount of fuel.

Clean appliance, including firepot, heat

exchangers and venting system. Remove

stainless steel baffle from firebox to clean

ash from on top of baffle. Clean behind rear

brick panels. Change fuel brand to pre-

mium.

Check that firepot clean-out plate is fully

closed.

Reduce feed rate using feed rate adjustment

control rod located inside hopper.

Nuisance shutdowns.

Low flame.

Sawdust buildup in hopper.

Feed motor is reversing.

Defective thermocouple.

Defective control box.
Firepot more than 1/2 full

Increase feed by opening feed rate adjust-

ment control rod located inside hopper.

Clean hopper, see page 34.

Check for good connections between feed

motor and wire harness.

Replace thermocouple.

Replace control box.
See page 37 for detailed instructions for

“High Ash Fuel Content Maintenance”.

Appliance calls for heat.

Call light illuminates.

Exhaust blower starts.

No feed or igniter.

Thermocouple is defective or not properly

plugged in.

Defective control box

Check connections on thermocouple or

replace if defective.

A flashing yellow light on the control box

indicates a problem with the thermocouple.

Replace control box.

Troubleshooting (Cont’d)