15. Soot and Fly Ash: Formation & Need for Removal

in Exhaust Venting System.

Frequency:

Yearly or more frequently depending on

ash build-up.

By:

Qualified Service Technician/Homeowner

Be sure the appliance is allowed to cool, has been unplugged

and the exhaust blower is off.
The products of combustion will contain small particles of fly

ash. The fly ash will collect in the exhaust venting system

and restrict the flow of the flue gases.
At start-up if there is incomplete combustion, or if there is a

shutdown or incorrect operation of the appliance it will lead

to some soot formation. This will collect in the exhaust vent-

ing system.
The venting system may need to be cleaned at least once a

year or more often depending upon the quality of your fuel

or if there is a lot of horizontal pipe sections. Ash will build

up more quickly in the horizontal sections.

16. Preparing Firebox for Non-Burn Season

Frequency:

Yearly

By:

Homeowner

a. Be sure the appliance is allowed to cool, has been

unplugged and the exhaust blower is off.

b. Remove all ash from the firebox and vacuum thoroughly.

c. Paint all exposed steel, including cast-iron.

• Use the Touch-Up paint supplied with the appliance;

or,

• Purchase paint from your local dealer.
• Must use a high-temperature paint made specifi-

cially for heating appliances.

13. Cleaning Exhaust Blower - Requires No Lubrication

Frequency:

Yearly or as needed

By:

Quality Service Technician/Homeowner

Task:

: Contact your local dealer.

14. Cleaning Convection Blower - Requires No

Lubrication

Frequency:

Yearly or as needed

By:

Qualified Service Technician

Task: Contact your local dealer.

12. Door Gasket Inspection

Frequency:

Prior to heating season

By:

Homeowner

a. Be sure the appliance is allowed to cool, has been

unplugged and the exhaust blower is off

b. To inspect the door rope (gasket), open the door and

see that the door rope extends approximately 1/8 inch

(3mm) to 3/16 inch (9.5mm) from the door rope chan-

nel.

c. It should show signs of compaction all the way around

the door where the rope contacts the face of the appli-

ance. Confirm there are no air leaks.