CB1200-I Pellet Insert

I. Optional Log Set Placement Instructions

CAUTION

Logs are FRAGILE. Use extreme care when handling or

cleaning logs.

NOTE:

Due to the abrasive nature of a pellet appliance fire, the

logs are not covered under warranty. Any placement vari-

ation other than shown here can cause excessive heat

and shall void the appliance warranty.

1. Place the front log in first as shown in Figure 25.1

charred area surrounding firepot.

2. Set the left and right logs onto the front log, placing

the holes in the base of the left and right logs over the

locating pins in the front log. See Figure 25.2. Ensure

that the charred ends are facing the firepot.

LOCATING PINS

Charred Areas in the Back

Top Log

Right

Top Log, Left

Front Log

Figure 25.1

Figure 25.2

1

.

A 12 volt AC thermostat is required to operate this pellet

appliance. You may use the included wall mount thermo-

stat or purchase an optional programmable thermostat

or remote control. The included thermostat is equipped

with an adjustable heat anticipator. The current rating is

.05 amps. The anticipator needs to be adjusted to the

lowest setting available.

2. When mounting a thermostat on a wall, be sure to follow

your thermostat installation instructions carefully.

NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted on
an inside wall and not in direct line with the appliance
convection air. Remove any packaging from inside
the thermostat before using.

NOTE: If the thermostat is located too close to the
appliance, you may need to set the temperature
setting slightly higher to maintain the desired tem-
perature in your home.

3. Open right side plane to access a 4 screw terminal block

located on the bottom right hand side next to the power

cord inlet. The center 2 screws are for the thermostat

wires. The outer 2 are the mounting screws for the ter-

minal block. Figure 25.3.

J. Thermostat Installation

Shock hazard.

• Do NOT remove grounding prong from plug.

• Plug directly into properly grounded 3 prong

receptacle.

• Route cord away from appliance.

• Do NOT route cord under or in front of appli-

ance.

CAUTION

Terminal Block

Center 2 Screws for

Thermostat Wires

Power Outlet

Figure 25.3