Reference Materials

7. Heat Exchangers
The heat exchangers transfer heat from the exhaust system

into convection air. There are 2 clean out rods located under

the heat exchangers.
8. Heat Output Switch
The heat output switch is located on the right side of firebox,

behind right side panel. The function of the heat output

switch is to regulate the burn rates; low, medium and high

settings.
9. Hopper Switch
The hopper switch is located in the upper right hand corner

of the hopper. This switch is designed to shut down the feed

motor whenever the hopper lid is opened.
10. Igniter
The igniter is mounted on the base of the firepot. Combustion

air travels over the red hot igniter creating super heated air

that ignites the pellets.
11. Junction Box And Wiring Harness
The junction box is located on the right side of the appliance,

behind the right front access panel. The junction box and

wiring harness are replaced as one component.
12. Power Supply
The power outlet is located on the right side of the appliance.

Check the wall receptacle for 120 volt, 60 Hz (standard

current). Make sure the outlet is grounded and has the correct

polarity. A good surge protector is recommended. When

operating with a generator you need at least 600 watts of

power, or with an inverter at least 800 watts of power, available

for the appliance during the start cycle.
13. Red Call Light
The red call light is on the right side behind the right side

panel. The function of the red call light is to indicate that the

thermostat is calling for heat.
14. Reset Button
The reset button is located on the right side of firebox

behind right side panel. The function of the reset button is

to momentarily open the thermostat circuit, which restarts

the system.
15. Thermocouple
The thermocouple is located on top of the firepot inside

the thermocouple cover (ceramic protection tube). The

thermocouple sends a millivolt signal to the control box

indicating the preset temperatures of the green and red lights

have been obtained.

When describing the location of a component

part it is always AS YOU FACE THE FRONT

OF THE APPLIANCE.

2. Convection Blower
The convection blower is mounted at the bottom rear of the

appliance. There are 2 impellers, one on each side of the

motor. The convection blower pushes heated air through the

heat exchange system into the room.
3. Combustion (Exhaust) Blower
The combustion blower is mounted on the left side of the

appliance behind the left side panel. It is accessible either

when the insert is pulled out onto the hearth or from both

hinged side openings. The blower is designed to pull the

exhaust from the appliance and push it out through the

venting system.
4. Feed System
The feed system is located behind the firebox and can be

removed as an entire assembly. The assembly includes

the feed motor, mounting bracket, bearing and feed spring

(auger). The hollow feed spring (auger) pulls pellets up the

feed tube from the hopper area and drops them down the

feed chute into the firepot.
5. Firepot

The firepot is made of high quality ductile iron and has a

cleaning pull-out rod. The floor of the firepot opens for

cleaning when you pull out the rod. Be sure that the floor

returns to a completely closed position or your appliance

will not operate properly.
6. Fuse
The fuse is located on the right side of the appliance behind

the side panel. The fuse will blow should a short occur and

shut off power to the appliance.

NOTE:

Do NOT open the control box. This will void the

warranty. If you need to plug in or remove the control

box you must first unplug the appliance.

1. Control Box
a. The control box is located on right side of appliance,

behind the right side panel.

b. There is a light located inside of the control box. The

internal light will turn green when the appliance has

reached a temperature of 200

o

F (93°C) in the firepot.

and will turn red when it reaches 600

o

F (315°C).

c. There is also an internal blue light located in the upper

left corner of the control box. When you plug in the

appliance the blue light will automatically start blinking

1 blink every 10 seconds for 60 seconds and then will

stop.