FUN 041

DIV

Unsigned double/single division

Expression

Input

−

[ A+1

⋅

A DIV B

→

C ]

−

Output

Function

When the input is ON, the double-word data of A+1

⋅

A is divided by the data of B, and the quotient

is stored in C and the remainder in C+1. The data range of A+1

⋅

A is 0 to 4294967295, and the data

range of B and C is 0 to 65535.
If the quotient is greater than 65535 (overflow), the limit value 65535 is stored in C, 0 is stored in
C+1, and the instruction error flag (ERF = S051) is set to ON.

Execution condition

Input

Operation

Output

ERF

OFF

No execution

OFF

−

ON

Normal execution (B

≠

0)

ON

−

Overflow (B

≠

0)

ON

Set

No execution (B

=

0)

OFF

Set

Operand

Name

Device

Register

Constant Index

X

Y

R

S

T.

C. XW YW RW SW T

C

D

I

J

K

A Dividend

√

√

√

√

√

√

√

√

B Divisor

√

√

√

√

√

√

√

√

C Quotient

√

√

√

√

√

√

Example

When R010 is ON, the double-word data of D0201

⋅

D0200 is divided by the constant data

4000, and the quotient is stored in D1000 and the remainder is stored in D1001.
If the data of D0201

⋅

D0200 is 332257, the quotient 83 is stored in D1000 and the remainder

257 is stored in D1001.

D0201

⋅

D0200

332257

÷

D1000

83

(quotient)

Constant

4000

D1001

257

(remainder)

Note

•

If

divisor

(operand

B) is 0, ERF (instruction error flag = S051) is set to ON.

The ERF (S051) can be reset to OFF by user program, e.g.

−

[ RST S051 ]

−

.

•

This instruction handles the register data as unsigned integer.

Advertising