6F3B0253

250

T1-16S User’s Manual

7. Instructions

Data table:

Register

Data contents

Signal direction

RW100

#0 Operating frequency

←

Read

RW101

#0 Output terminal status

←

Read

RW102

No use

RW103

No use

RW104

#1 Operating frequency

←

Read

RW105

#1 Output terminal status

←

Read

RW106

No use

RW107

No use

RW176

#19 Operating frequency

←

Read

RW177

#19 Output terminal status

←

Read

RW178

No use

RW179

No use

•

The data format for the operating frequency register is 0.01 Hz units. For example, if it is 60 Hz, the
corresponding register data is 6000.

•

The bit assignment of the output terminal status register is as follows. For details, refer to your
Inverter manual.

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

OUT1 (f130)

OUT2 (f131)

FL (f132)

R1 (f133)

R2 (f134)

OUT3 (f135)

OUT4 (f136)

ALM0

ALM1

ALM2

ALM3

Example operation:

The current operating frequency and the output terminal status of the #0 Inverter are stored in RW100
and RW101 respectively.
If the #0 Inverter is operating at 55 Hz, the data 5500 is stored in RW100. If the OUT2 terminal of the
#0 Inverter is ON, the bit 1 of RW101 (R1011) becomes 1.