Instructions fun 236 xfer expanded data transfer – Toshiba 6F3B0253 User Manual

Page 243

Advertising
background image

6F3B0253

Basic Hardware and Function

241

7. Instructions

FUN 236

XFER

Expanded data transfer

Expression

Input

−

[ A XFER B

→

C ]

−

Output

Function

When the input is ON, data block transfer is performed between the source which is indirectly
designated by A and A+1 and the destination which is indirectly designated by C and C+1. The
transfer size (number of words) is designated by B.
The transfer size is 1 to 256 words. (except for writing into EEPROM)
Data transfer between the following objects are available.

•

CPU register (RW or D)

↔

EEPROM (D register)

•

CPU register (RW or D)

↔

T1S RS-485 port (T1S only)

Execution condition

Input

Operation

Output

ERF

OFF

No execution

OFF

−

ON

Normal execution

ON

−

When error is occurred (see Note)

ON

Set

Operand

Name

Device

Register

Constant Index

X

Y

R

S

T.

C. XW YW RW SW T

C

D

I

J

K

A Source

parameter

√

√

√

√

√

√

√

B Transfer size

√

√

√

√

√

√

√

C Destination

parameter

√

√

√

√

√

√

Parameters

Source parameter

Transfer size and status

Destination parameter

A

Type

B

Transfer size

C

Type

A+1

Leading address

B+1

Status flag for RS-485 port

C+1

Leading address

B+2

(max. 2 words)

Register type

Type code

Leading address

Transfer size

RW register (RAM)

H0003

0 to 255

1 to 256

D register (RAM)

H0004

0 to 4095

1 to 256

D register (EEPROM)

H0020

0 to 2047

1 to 32 (if destination)

1 to 256 (if source)

T1S RS-485 port

H0030

0 (fixed)

1 to 256

Advertising