Using the Linux tool

On the top of the window the MAC address of the device is displayed. To detect
the MAC address manually, press the button “Refresh”. The displayed MAC
address is the same MAC address printed on the white sticker placed on the
back of the B050-000. The Linux setup tool does currently not support device
configuration via the USB interface. Please use either a network connection or
the serial console for the initial device configuration.

Furthermore, there are two buttons on the window: “Query Device” and “Setup
Device”. Press the “Query Device” button to display the preconfigured values
of the network configuration. The values are displayed in the text fields lo-
cated nearby. If necessary, adjust the network settings to your needs. To save the
changes enter an user name and an according password. Then press the “Setup
Device” button.

Authentication

To adjust the authentication settings, enter your login as a superuser and change your
password.

Super user login

Enter the login name of the super user. The initial value is “super”.

Super user password

Enter the current password for the super user. This initial value is “pass”.

New super user password

Enter the new password for the super user.

New password (confirm)

Re-type the new password for the super user.

To close the window and accept the changes press the “OK” button, otherwise press
the “Cancel” button (on Windows). On a Linux system close the window by the ap-
propiate button of the window frame.

Configuration via Serial Interface

To configure the B050-000 via serial interface both a serial port replicator cable and a
null modem cable are required. . (available separately).

Connect the Null Modem Cable to the serial interface with the black connector on the
port replicator.

The serial interface needs to be adjusted with the parameters as shown in Table 1-2.

Table 1-2. Serial parameters

Parameter

Value

Bits/second

115200

Data bits

8

Parity

no

6