Publication No. GEG-99197

May 04

7-44

TallyGenicom mL450 Laser Printer User Manual
Custom Page size and Microsoft Word, Word 2000, and Word 2003

RS-232C Serial Cable Pin Assignments

Eight pins of the 25-pin serial cable are utilized for the RS-232C standard:

RS-422 Serial Cable Pin Assignments

Five pins of the 25-pin serial cable are utilized for the RS-422 standard:

Troubleshooting

This section discusses troubleshooting error messages appearing on the printer’s control panel.
Sources of help, information and technical support are also discussed.

Control Panel Error Messages

The format of control panel error messages is:

NETx: ERROR y

Pin No.

Signal

Direction

Description

1

GND

Frame Ground

2

TXD

Out

Transmit Data

3

RXD

In

Receive Data

4

RTS

Request To Send

5

CTS

In

Clear To Send

6

DSR

In

Data Set Ready

7

GND

Logic Ground

20

DTR

Out

Data Terminal Ready

Pin No.

Signal

Direction

Description

1

GND

Frame Ground

15

RXD -

In

Receive Data +

17

RXD +

In

Receive Data -

19

TXD -

Out

Transmit Data -

25

TXD +

Out

Transmit Data +