Input function selection from the CC-Link.

The function numbers selection of the RYn2 to RYn8 function valid from the command of the CC-Link are following
boldface numbers.

Positive logic Negative logic

Function

Speed control PM control

V/f

0

1

No function is assigned

/●

2

3 Forward

run

command

/●

4

5 Reverse

run

command

/●

6

7 Standby

/●

8

9 Reset

command

/●

10

11

Preset speed command 1

/●

12

13

Preset speed command 2

/●

14

15

Preset speed command 3

/●

16

17

Preset speed command 4

/●

18

19 Jog

run

mode

/●

20

21

Emergency stop by external signal *

/●

22

23 DC

braking

command

/●

24

25 2nd

acceleration/deceleration

/●

26

27 3rd

acceleration/deceleration

/●

28

29

2nd V/F control mode switching

/●

32

33

2nd stall prevention level

/●

36

37

PID control prohibition

/●

46

47

External thermal error input

/●

48

49

Forced local from communication

/●

50

51

Operation hold (hold of 3-wire operation)

/●

52

53

PID integral/differential clear

/●

54

55

PID characteristics switching

/●

56

57

Forced run operation

/●

58

59

Fire speed operation

/●

60

61 Acceleration/deceleration

suspend

signal

/●

62

63

Power failure synchronized signal

/●

64

65

My function-S trigger signal

/●

74

75

Integrating wattmeter(kWh) display clear

/●

76

77

Trace back trigger signal

/●

78

79

Light-load high-speed operation

prohibitive signal

/●

80

81

Holding of RY-RC terminal output

/●

82

83

Holding of OUT terminal output

/●

88

89 Frequency

UP

/●

90

91 Frequency

DOWN

/●

92

93

Clear frequency UP/DOWN

/●

96

97 Coast

stop

command

/●

98

99 Forward/reverse

selection

/●

100

101 Run/Stop

command

/●

104

105

Frequency setting mode forced switching

/●

106

107

Frequency setting mode terminal block

/●

108

109

Command mode terminal block

/●

110

111 Parameter

editing

permission

/●

120

121

Fast stop command 1

/●

122

123

Fast stop command 2

/●

134

135

Traverse permission signal

/●

136

137

Low voltage operation signal

/●

140

141

Forward deceleration

/●

142

143

Forward stop

/●

144

145

Reverse deceleration

/●

146

147

Reverse stop

/●

152

153

No.2 motor switching

(AD2 + VF2 + OCS2)

/●

200

201

Parameter editing prohibition

/●

202

203

Parameter reading prohibition

/●

* This function is not dependent on cmod.