- 22 -

■

Input function selection from the CC-Link.

The function numbers selection of the RYn2 to RYn8 function valid from the command of the CC-Link are following
boldface numbers.

Positive logic Negative logic

Function

Speed control PM control

V/f

0

1

No function is assigned

●

/●

●

●

2

3 Forward

run

command

●

/●

●

●

4

5 Reverse

run

command

●

/●

●

●

6

7 Standby

●

/●

●

●

8

9 Reset

command

●

/●

●

●

10

11

Preset speed command 1

●

/●

●

●

12

13

Preset speed command 2

●

/●

●

●

14

15

Preset speed command 3

●

/●

●

●

16

17

Preset speed command 4

●

/●

●

●

18

19 Jog

run

mode

●

/●

●

●

20

21

Emergency stop by external signal *

●

/●

●

●

22

23 DC

braking

command

●

/●

●

●

24

25 2nd

acceleration/deceleration

●

/●

●

●

26

27 3rd

acceleration/deceleration

●

/●

●

●

28

29

2nd V/F control mode switching

●

/●

●

●

32

33

2nd stall prevention level

●

/●

●

●

36

37

PID control prohibition

●

/●

●

●

46

47

External thermal error input

●

/●

●

●

48

49

Forced local from communication

●

/●

●

●

50

51

Operation hold (hold of 3-wire operation)

●

/●

●

●

52

53

PID integral/differential clear

●

/●

●

●

54

55

PID characteristics switching

●

/●

●

●

56

57

Forced run operation

●

/●

●

●

58

59

Fire speed operation

●

/●

●

●

60

61 Acceleration/deceleration

suspend

signal

●

/●

●

●

62

63

Power failure synchronized signal

●

/●

●

●

64

65

My function-S trigger signal

●

/●

●

●

74

75

Integrating wattmeter(kWh) display clear

●

/●

●

●

76

77

Trace back trigger signal

●

/●

●

●

78

79

Light-load high-speed operation

prohibitive signal

●

/●

●

●

80

81

Holding of RY-RC terminal output

●

/●

●

●

82

83

Holding of OUT terminal output

●

/●

●

●

88

89 Frequency

UP

●

/●

●

●

90

91 Frequency

DOWN

●

/●

●

●

92

93

Clear frequency UP/DOWN

●

/●

●

●

96

97 Coast

stop

command

●

/●

●

●

98

99 Forward/reverse

selection

●

/●

●

●

100

101 Run/Stop

command

●

/●

●

●

104

105

Frequency setting mode forced switching

●

/●

●

●

106

107

Frequency setting mode terminal block

●

/●

●

●

108

109

Command mode terminal block

●

/●

●

●

110

111 Parameter

editing

permission

●

/●

●

●

120

121

Fast stop command 1

●

/●

●

●

122

123

Fast stop command 2

●

/●

●

●

134

135

Traverse permission signal

●

/●

●

●

136

137

Low voltage operation signal

●

/●

●

●

140

141

Forward deceleration

●

/●

●

●

142

143

Forward stop

●

/●

●

●

144

145

Reverse deceleration

●

/●

●

●

146

147

Reverse stop

●

/●

●

●

152

153

No.2 motor switching

(AD2 + VF2 + OCS2)

●

/●

●

●

200

201

Parameter editing prohibition

●

/●

●

●

202

203

Parameter reading prohibition

●

/●

●

●

* This function is not dependent on cmod.