Unusual diagnosis, Option error, Disconnection error of network cable – Toshiba TOSVERT VF-S15 series option unit Function E6581830 User Manual

Page 48

Advertising
background image

E658130

- 47 -

7.

Unusual diagnosis

7.1. Option error

The error message is displayed when there is hardware error, software error or lose of
connection of wire.


▼

Display of trip information

e

-

23

(Optional unit fault 2 : 0037H) : Option error

7.2. Disconnection error of network cable

▼Display of trip information

err8

(

Optional unit fault 1

: 001BH):

Network error stop

*If a network error occurs when c101 is set to "4", it is displayed.

▼

Related parameter

Title Function Setting

range

Description

c100

Communication error
detection delay time

0.0 to100.0 sec

The waiting time from when a network error occurs
can be adjusted. If a network error continues past the
time set in c100, it is recognized as a
communication error and the operation of the inverter
follows the setting of c101.
When normal communication returns during the
setting time, a communication error is not displayed
and operation is continued.

*

Time-out time

= CC-Link network time out

+ c100

(communication error detection delay time) [0.1s]

c101

Inverter operation at the
communications loss action

0 to 5

The operation of the drive when the communication
fault occurs can be specified.

c102

Preset speed operation
selection

0 to 15

The operation frequency of the drive when the
communication fault occurs can be specified. (Only
when c101 is set to 5)

c103

Communication time-out
condition selection

0 to 2

Select the communication time-out condition.


Advertising