6.

Programming examples

This chapter provides programming examples which control the inverter with the PLC.

Item

Programming Example

Refer to Page

6.1

Reading the inverter status

Reading the inverter status from the buffer

memory of the master station.

- 38 -

6.2

Setting the command mode

Command mode from CC-Link is confirmed.

- 39 -

6.3

Setting the operation commands

Commanding the forward rotation.

- 40 -

6.4

Setting the reference frequency

Setting to 50.00Hz.

- 40 -

6.5

Setting the monitoring function

Monitoring the output frequency.

- 41 -

6.6

Writing a parameter value

Setting the f311 [Reverse-run prohibition

selection] to [1 : Prohibit reverse run].

- 42 -

6.7

Reading a parameter value

Reading the parameter f311.

- 42 -

6.8

Reading the the fault record

Reading the fault record

- 44 -

6.9

Inverter reset

Resetting the inverter.

- 45 -

System configuration for programming example

PS Q02 QJ61 Input Output

Unit CPU BT11N Unit Unit

(X/Y00 (X20 (Y30

to 1F) to X2F) to 3F)

Master unit

Station 1
Inverter

Station 2

Inverter

X0020

CC-Link communication cable

Y30

The example of CC-Link communication network composition

・

CPU Mitsubishi Electric Corp.

Q02CPU

・

Master unit Mitsubishi Electric Corp.

QJ61BT11N

・

Input module

Mitsubishi Electric Corp.

QX40

・

Output module Mitsubishi Electric Corp.

QY40P

・

CC-Link dedicated cable

Kuramo Electric Corp.

FANC-110SBH

・

Inveter Toshiba

TOSVERT VF-S15(2 uints)

One station is occupied

・

CC-Link option

Toshiba

CCL003Z(2 units)