Description of monitor code – Toshiba TOSVERT VF-S15 series option unit Function E6581830 User Manual
Page 34

E658130
- 33 -
5.5.11.
Description of monitor code
Divide the monitor code (RWw n) into half and select the monitor value 1 (RWr n) from the
lower 8 bits and the monitor value 2 (RWr n) from the upper 8 bits.
For Example: When output voltage is selected for the monitor value 1 and output torque is
selected for the monitor value 2. -> The monitor code is 0703H.
Address
Upper 8 bits
Lower 8 bits
RWw n
Monitor value
2
Monitor value 1
RWw n+4
-
Monitor value 3
RWw n+5
-
Monitor value 4
RWw n+6
-
Monitor value 5
RWw n+7
-
Monitor value 6
Monitor code (When an invalid monitor code is set up, monitor value fixes to 0.)
Code Number
Second Monitor Description
(upper 8 bits)
First Monitor Description
(lower 8 bits)
Unit
00H
Output frequency
(Only the second monitor )
None monitor (Monitor value is 0)
0.01Hz
01H Output
frequency
Output
frequency
0.01Hz
02H Output
current
Output
current
0.01A
03H Output
voltage
Output
voltage
0.1V
04H
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
05H
Frequency command value
Frequency command value
0.01Hz
06H Output
speed
Output
speed
1min
-1
07H
Output torque (With sign)
Output torque (With sign)
0.1%
08H
DC voltage
DC voltage
0.1V
09H
PBR load factor
PBR load factor
0.1%
0AH
Motor overload factor
Motor overload factor
0.1%
0BH・0CH
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
0DH
Input power
Input power
0.01kW
0EH Output
power
Output
power
0.01kW
0FH
Input terminal information
Input terminal information
-
10H
Output terminal information
Output terminal information
-
11H Output
current
Output
current
0.1%
12H
Exciting current
Exciting current
0.01A
13H
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
14H
Cumulative operation time
Cumulative operation time
1h
15H・16H
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
17H
Accumulation power supply ON time
Accumulation power supply ON time
1h
18H
Motor overload factor
Motor overload factor
0.1%
19H
Integral input power
Integral input power
1kWh
1AH
Integral output power
Integral output power
1kWh
1BH Analog
input(VIA)
Analog input(VIA)
0.01%
1CH
Analog input(VIB) (With sign)
Analog input(VIB) (With sign)
0.01%
1DH Analog
input(VIC)
Analog
input(VIC)
0.01%
1EH・1FH
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
21H
Torque current (With sign)
Torque current (With sign)
0.1%
22H
None monitor (Monitor value is 0)
None monitor (Monitor value is 0)
-
23H
Factory specific monitor
Factory specific monitor
―
24H
PID feedback value
PID feedback value
0.01Hz