2. Remote register (Inverter -> Master)

RWr

Address Signal

Description

RWr n

Monitor value 1

When (RYnC) is on, the monitored value specified to the lower 8 bits of
the monitor code (RWwn) is set.

RWrn+1

Monitor value 2

(output frequency)

When "0" is set to the higher 8 bits of the monitor code (RWwn), the
current output frequency is always set. When other than "0" is set to the

upper 8 bits of the monitor code (RWwn) and (RYnC) is on, the

monitored value specified to the higher 8 bits of the monitor code
(RWwn) is set.

RWrn+2

Response code 1

When (RYnF) is on, the response code correspond to the instruction
code of (RWwn+2) is set. The value "0" is set for a normal reply and
other than "0" is set for data fault, mode error, etc.

RWrn+3

Read data 1

For a normal reply, the reply data to the instruction specified by the
instruction code is set.

RWrn+4

Monitor value 3

When (RYnC) is on, the monitored value specified to the monitor code
(RWw n+4) is set.

RWrn+5

Monitor value 4

When (RYnC) is on, the monitored value specified to the monitor code
(RWw n+5) is set.

RWrn+6

Monitor value 5

When (RYnC) is on, the monitored value specified to the monitor code
(RWw n+6) is set.

RWrn+7

Monitor value 6

When (RYnC) is on, the monitored value specified to the monitor code
(RWw n+7) is set.

RWrn+8

Trip information

(Trip code)

The fault data of the trip history No. specified by (RWw n+8) is stored in
the lower 8bits.
The trip history No. specified is echo backed to the upper 8bits.

RWrn+9

Trip information

(output frequency)

Output frequency of the trip history No. specified in (RWw n+8) is
stored.

RWrn+A

Trip information

(output current)

Output current of the trip history No. specified in (RWw n+8) is stored.

RWrn+B

Trip information
(output voltage)

Output voltage of the trip history No. specified in (RWw n+8) is stored.

RWrn+C

Trip information

(energization time)

Energization time of the trip history No. specified in (RWw n+8) is
stored.

RWrn+D

to

RWrn+F

Reserved

Do not use it.

RWrn+10

Reply code 2

When (RYnF) is on, the response code correspond to the instruction
code of (RWw n+10) is set. The value "0" is set for a normal reply and
other than "0" is set for data fault, mode error, etc.

RWrn+11

Read data 2

For a normal reply, the reply data to the instruction specified by the
instruction code is set.

RWrn+12

Reply code 3

When (RYnF) is on, the response code correspond to the instruction
code of (RWw n+12) is set. The value "0" is set for a normal reply and
other than "0" is set for data fault, mode error, etc.