S0 auto answer ring number, S1 ring counter, S2 at escape character (user defined) – Toshiba M30 User Manual

Page 196

Advertising
background image

User's Manual

D-2

A

PPENDIX

D

S0

Auto answer ring number

This register determines the number of rings the modem will count
before automatically answering a call. Enter 0 (zero) if you do not want
the modem to automatically answer at all. When disabled, the modem
can only answer with an ATA command.

Range: 0-255

Default: 0

Units:

rings

S1

Ring counter

This register is read only. The value of S1 is incremented with each ring.
If no ring occurs over a six-second interval, this register is cleared.

Range: 0-225

Default: 0

Units:

rings

S2

AT escape character (user defined)

This register determines the ASCII values used for an escape sequence.
The default is the + character. The escape sequence allows the modem
to exit data mode and enter command mode when online. Values greater
than 127 disable the escape sequence.

Range: 0-255, ASCII decimal

Default: 43

Units:

ASCII

S3

Command line termination character
(user defined)

This register determines the ASCII values as the carriage return
character. This character is used to end command lines and result
codes.

Range: 0-127, ASCII decimal

Default: 13 (carriage return)

Units:

ASCII