Accessory parts and Parts to be procured locally

H

Accessory parts

Refrigerant piping

• Piping material used for the conventional refrigerant cannot be used.

• Use copper pipe only with a wall thickness of 0.8 mm or more for Ш6.4, Ш9.5, Ш12.7.

• Flare nut and flare operations are also different from those of the conventional refrigerant.

Use the flare nut fitted to the indoor unit of the air conditioner.

Shape

This manual

——

M5 × 16L

Part name

Installation Manual

Heat insulating pipe

Installation pattern

Installation gauge

Pattern fixing screw

Heat insulator

Washer

Hose band

Flexible hose

Heat insulator A

Heat insulator B

Q’ty

1

2

1

2

4

1

8

1

1

1

1

Usage

(Ensure handover to customer)

For heat insulation of the pipe connecting section

For checking of ceiling opening and the main unit position

For positioning of the ceiling position
(To be used with the installation pattern)

For attach the installation pattern

For heat insulation of drain connecting section

For hanging unit

For connecting drain pipe

For adjusting core-out of drain pipe

For sealing of wire connecting port

For sealing of wire connecting port