COMPONENT CHECKS

Continuity checks can be made on various components of the washer from the connectors on the
Central Control Unit. Before performing any of these tests, disconnect the washer from the wall
outlet. In addition, disconnect the wiring harness connector from the Central Control Unit before
making any continuity tests.

Pressure Switch

The pressure switch can be checked at various water levels. Disconnect the pressure switch
connector from the control box.

6

1

5 4 3 2

Water Level

Test Points

Reading

Empty

4 to 6

0 ohms

Suds Detect

1 to 2

0 ohms

L1

4 to 5

0 ohms

Overflow

3 to 4

0 ohms

Temperature Sensor

Results

35.9K

9.7K

6.6K

4.6K

3.2K

2.3K

1K

Temperature

32° F (0° C)

86 ° F (30° C)

104° F (40° C)
122° F (50° C)
140° F (60° C)
158° F (70° C)
203° F (95° C)

Dispenser Switch and Motor

6 3 1

Test Points

Reading

Switch

6 to 5

0 ohms

Motor

3 to 1

1400 ohms

!

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect power before servicing.

Replace all panels before operating.

Failure to do so can result in death or electrical shock.