Serial Communication Error

Communication between the Central Control Unit (CCU) and the Motor Control Unit
(MCU) cannot be sent correctly.

Potential Causes

Check Wire Harness connections to the MCU, the motor, and Central Control
Unit (CCU)

Check the Drive system for any worn or failed components

Check MCU

Check CCU

Check Motor

Check Wire Harness

Dispenser Circuit Error

If the dispenser motor is not able to be driven to it’s proper position.

Potential Causes

Check mechanical linkage from dispenser motor to the top of the dispenser.

Check Wire Harness connections to the dispenser motor and Central Control
Unit (CCU)

Check Dispenser Motor

EEPROM Error

The Central Control Unit (CCU) receives it’s data from an EEPROM onboard the
CCU. If there is an error reading this data it will cause this error.

Potential Causes

A power glitch may cause this error. Try unplugging the Unit for two minutes to
see if that fixes the error.

Check CCU.

Motor Control Unit (MCU) Error

If the MCU detects multiple resets or errors during a wash cycle it will go into this
error mode.

Potential Causes

Check Wire Harness connections to the MCU, the motor, and Central Control
Unit (CCU)

Check Drive belt

Check MCU

Check Motor

Check Wire Harness

SUDS LOCK (Overdose of Detergent detected during the Wash Cycle)

The motor control unit senses a suds lock condition by analyzing the current draw on
the drive motor. If “Sud” is displayed a potential suds lock is detected. This may
signify a bad pump, an extra heavy load, excessive detergent, or excessive suds.

ERROR CODES

DISPLAY

EXPLANATION AND RECOMMENDED PROCEDURE

F/11

F/13

F/14

F/15

Sud