Indication

C:00

C:01

C:02

C:03

C:04

C:05

C:06

C:07

C:08

Control Action

Door is Locked

Filling by cold water inlet valve

Distribution system is set to Prewash position

Fill by hot water inlet valve

Basket rotates clockwise at wash speed

Heater is switched ON.

Basket rotates clockwise with wash speed.

If there is not enough water in the tub, the

water inlet valve will be switched ON to fill-in

the minimum water quantity.

NOTE: On GHW 9100 Models only the

Temperature Sensor will be checked

Drain Pump is ON

Basket rotates counterclockwise

from 35 to 90 rpm
within 15 seconds

Basket rotates counterclockwise

with max. speed

Basket speed > 1100 rpm

Actuators to be Checked

Door Lock System

Flowmeter, Cold water inlet valve

Dispenser motor,

Dispenser contact

Hot water inlet valve

Motor, MCU control

Heater, Temperature Sensor

Drain Pump

Motor, MCU control

Motor, MCU control

DIAGNOSTIC TEST

The control must be in the OFF state before pressing the touch-pad sequence to start the test.

Starting the test mode

Close the door.
Press the Control On button.
Select the DRAIN/SPIN cycle.
Select NO SPIN by pressing the SPIN SELECT button, as needed.
Push Prewash Option button four (4) times within five (5) seconds. C:00 will show in the display.
NOTE: If Model does not have PREWASH Mode as an option, press RINSE/HOLD.

If the Starting procedure fails, push PAUSE/CANCEL button. Then repeat the starting sequence.

Test Program Control during Execution

To advance to the next step of the test procedure, push Prewash Option button two (2) times.