Error codes, Display explanation and recommended procedure – Whirlpool GHW9100L User Manual

Page 49

Advertising
background image

6 - 5

ERROR CODES

DISPLAY

EXPLANATION AND RECOMMENDED PROCEDURE

Drive Motor Tachometer Error

The control is unable to properly detect motor speed and the machine will shut down.
If a failure occurs during high-speed spin the door will be unlocked after 3 minutes.

Potential Causes

Check wire harness connections between the Drive Motor/Tachometer and the
Motor ControlUnit (MCU), and between the MCU and the Central Control Unit
(CCU)

Check the Drive Motor

Check the MCU

Check the Wire Harness

Motor Control Unit Error

The

Central Control Unit

has detected a short in the motor control unit. If a failure

occurs during high-speed spin the door will be unlocked after 3 minutes.

Potential Causes

Check wire harness connections between the Drive Motor and the Motor Control
Unit (MCU), and between the MCU and the Central Control Unit (CCU)

Check the MCU

Check the Drive Motor

Check the Wire Harness

Overflow Condition

If the Overflow contact on the pressure switch is Closed for more than 60 seconds
an Overflow condition will occur. In an Overflow condition, the Door will remain
locked, and the Drain Pump will run constantly, even if PAUSE/CANCEL is pressed
twice and the Display is cleared. Unplug the unit to service.

Potential Causes

Check the drain hose and make sure it is not plugged or kinked

Check Wire Harness connections to the Drain Pump, Pressure Switch, and
Central Control Unit (CCU)

Check/ Clean Drain Pump Filter of foreign objects

Check for Drain Pump Failure

Check the Inlet Valve for proper shut off

Check the Pressure switch for proper operation

Motor Control Unit (MCU) Heat Sink Thermal Trip

If the thermal protector on the MCU heat sink gets too hot, it will open the thermal
protector on the heat sink which will stop motor functions and an “F/10” will be
displayed.

Potential Causes

Check for Proper Installation, verify the unit is not located near a source of heat
and has proper ventilation.

Check Wire Harness connections to the MCU, the motor, and Central Control
Unit (CCU)

Check the Drive system for any worn or failed components

Check MCU

Check Motor

F/07

F/06

F/09

F/10

Advertising
This manual is related to the following products: