1. Monitor Mode: Enables/disables the Monitor Mode

feature. Do not enable the Monitor Mode until you have

finished selecting the other Monitor Mode parameters.

(Default = Off.)

2. Switch If Level: Determines which line condition will

cause the selected A/B circuits to switch. This item can

either be set to "0 - Low" or "1 - High". When this item is

set at "0 - Low", the selected A/B circuit(s) will be

switched when the line goes low. When this item is set at

"1 - High", the selected A/B circuit(s) will be switched

when the line goes high. (Default = "0 - Low".)

3. Switch to Position: Determines which A/B line will be

automatically selected when the line goes to the target

level (Item 2.) For example, if Item 2 is set at "0 - Low"

and Item 3 is set at "B", then the monitored line goes low,

the selected A/B circuit(s) will be switched to Line B.

(Default = B.)

4. Delay Period: Determines how long the monitored line

must remain at the target level (Item 2) in order to trigger

automatic A/B switching. For example, if the target level

is "1 - High" and the Delay Period is 1 minute, then the

selected A/B circuits will be switched when the monitored

line remains high for 1 minute. (Default = 5 Seconds.)
Note: When Item 5 (Return) is enabled, the Delay

Period also determines how long the line must return

to (and remain at) the normal state in order for the

A/B line to be switched back to it's original setting.

5-14

PLS-345 - Physical Layer Switch; User's Guide

MONITOR PARAMETERS:

1. Monitor Mode:

On

2. Switch If Level:

0 - Low

3. Switch to Position: B

4. Delay Period:

.5 Secs

5. Return:

On

6. Circuits to Switch: 2, 3

Enter Selection or <ESC> to Exit ...

Figure 5.6: The Monitor Mode Parameters Menu