7.2. Code Activated A/B Switching

The PLS offers three different commands for controlling A/B

switching:

·

The /A command, which is used to switch one or more

circuits to the "A" line.

·

The /B command, which is used to switch one or more

circuits to the "B" line.

·

The /D command, which is used to switch all three circuits

to their user-defined default A/B positions.

All three of these commands are available in both System Mode

and User Mode.

7.2.1.

The /A Command and the /B Command

The /A command and the /B command can be used to control the

"A" or "B" position of one or more of the A/B circuits. The /A

command will switch one or more circuits to the "A" line, and

the /B command will switch one or more circuits to the "B" line.
Both the /A command and the /B command use the following

format:

/A <n> [Enter] or /B <n> [Enter]

Where, n is one of the following:

·

Switch One Circuit: To switch one A/B circuit, enter the

number or common name of the desired circuit. For

example, to switch circuit 2 to the "A" position, type

/A 2 [Enter].

·

Switch Two Circuits: To switch two circuits to the same

A/B position, enter the numbers or common names of the

desired circuits with a "plus" sign (+) between them (e.g.

n+N). For example to switch circuits 1 and 3 to the "B"

position, type /B 1+3 [Enter].

·

Switch All Circuits: To switch all three A/B circuits to the

same A/B position, enter an asterisk (*) in place of the

circuit number or name. For example, to switch all three

circuits to the "A" position, type /A * [Enter].

7-2

PLS-345 - Physical Layer Switch; User's Guide