Operation – Western Telematic PLS-345 User Manual

Page 39

Advertising
background image

7.

Operation

The PLS-345 offers three different methods for switching

A/B paths:

1. Manual A/B Switching: The manual A/B Switches on the

PLS front panel are used to initiate switching of one or

more A/B Circuits.

2. Code Activated A/B Switching: ASCII commands are

sent to the PLS to initiate switching of one or more

A/B Circuits.

3. Automated A/B Switching (Monitor Mode): The PLS

monitors a signal received via the Monitor Input Port, and

switches one or more A/B Circuits according to

user-defined parameters.

These methods are discussed in the sections that follow.

7.1. Manual A/B Switching

The most basic method for switching A/B paths is accomplished

using the manual A/B switches on the PLS front panel. When

performing Manual A/B switching, note the following:

·

The Master A/B Switch (Labeled "All") can be used to

switch all three A/B Circuits.

·

When an A/B Circuit is switched, the corresponding LED

indicators on the instrument front panel and back panel will

light.