Chapter 42 Command Examples

IES-612-51A User’s Guide

279

Sync with timeserver

<ip> failed!

WARN

The device was not able to synchronize the time with the time server at the
listed IP address.

Sync with timeserver

<ip> successful!

INFO

The device synchronized the time with the time server at the listed IP
address.

Received File <file>!

INFO

A file was uploaded to the IES-612-51A by FTP.
<file> - received file’s name

Received Firmware

Checksum Error!

WARN

A checksum error was detected during an attempted FTP firmware upload.

Received Firmware

Invalid!

WARN

Someone attempted to upload a firmware file with a wrong identity via FTP.

Received Firmware Size

too large!

WARN

The file size was too large with an attempted FTP firmware upload.

THERMO LOW VOLTAGE:

dev: <id> limit:

<threshold> value:

<voltage>!

WARN

The device’s voltage went above the accepted operating range.
<id> 1=1.2 V, 2=1.8 V, 3=3.3 V, 4=18 V
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged

THERMO LOW

TEMPERATURE: dev:<id>

threshold:<threshold>

(degree C)

value:<temp>(degree

C)!

WARN

The temperature was too low at one of the temperature sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged

THERMO OVER

TEMPERATURE: dev:<id>

threshold:<threshold>

(degree C)

value:<temp>(degree

C)!

WARN

The temperature was too high at one of the temperature sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged

THERMO OVER

TEMPERATURE released:

dev:<id>

threshold:<threshold>

(degree C)

value:<temp>(degree

C)!

INFO

The temperature at one of the temperature sensors has come back to
normal.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged

THERMO OVER VOLTAGE:

dev: <id> limit:

<threshold> value:

<voltage>!

WARN

The voltage at one of the voltage sensors went above the accepted
operating range.
<id> 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged

THERMO OVER VOLTAGE

released:

nominal:<nominal>(mV)

value:<voltage> (mV)!

INFO

The device’s voltage is back inside the accepted operating range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged

Table 90 Log Messages (continued)

LOG MESSAGE

TYPE

DESCRIPTION