Xantrex Technology GT5.0-NA User Manual

Page 53

Advertising
background image

Front Panel Display Screens and What They Mean

975-0320-01-01

5–5

Additional screens
for multiple units

In addition to the normal system message screens, additional screens specific to
each GT Inverter unit can be displayed when the unit is networked to other GT
Inverters. These screens are only available on multiple unit systems.

To view unit-specific screens in a multiple unit system:

1. Tap the Xantrex logo near the LCD to advance the display to the next screen.

Continue tapping until the final system message screen (“Grid Readings”, in
Table 5-3 above) is displayed.

2. Tap again. Normal operation screens shown in Table 5-4 are displayed in the

order given, as you tap successively on the unit.

If you continue to tap the unit, then the LCD will cycle through all of the available
normal operation screens. Each message is displayed for up to 30 seconds. If you
do not tap again within that time period, then the LCD backlight turns off and the
display reverts to the default normal operation screen (Table 5-2).

Table 5-3 Normal Operation Screens for All GT Inverter Units

Tap

Display*

* In a multiple unit system with network cables properly installed, the system

values displayed are for the entire system. For example, in a two-inverter
system, if inverter #1 is producing 1500 W and inverter #2 is producing
2000 W, both inverters display a total system power of 3500 W. Time online
and array readings are for the local inverter and PV array associated with that
inverter.

Description

1st time

System 2000W

Today 2.500kWh

LCD backlight turns on for better readability
and default Normal Operation screen is
displayed.

2nd time

System Lifetime

305kWh

Lifetime energy produced by the GT Inverter
system.

3rd time

Time Online

Today hh:mm:ss

Length of time inverter has been online today, in
hours (hh), minutes (mm) and seconds (ss).

4th time

Array Readings

350.5V

8.4A

Immediate DC voltage and current readings
from the PV array.

5th time

Grid Readings

242.6V

60.0Hz

Immediate AC voltage and frequency readings
from the Grid

Table 5-4 Additional Normal Operation Screens for Each GT Inverter Unit in a
Multiple Unit System

Tap

Display

Description

6th time

Unit 1500W

Today 1.250kWh

Power being produced by this unit now.
Cumulative energy produced by this unit today.

7th time

Unit Lifetime

150kWh

Lifetime energy produced by this GT Inverter unit

Advertising