Output Power Versus Ambient Temperature

Once the heat sink on the inverter reaches a maximum temperature limit, the GT
Inverter reduces its energy output to ensure maximum component ratings are not
exceeded.

Setting

Default

Range

Tolerance

Phase-to-phase (rms) high threshold voltage

261.00

261.00–264.00

±3 V

Phase-to-phase (rms) low threshold voltage

214.00

204.00–214.00

Phase-to-neutral (rms) high threshold voltage

130.50

130.50–132.00

±1.5 V

Phase-to-neutral (rms) low threshold voltage

107.10

102.00–107.10

Frequency high threshold

60.40

60.40–60.60

±0.1 Hz

Frequency low threshold

59.40

57.00–59.80

Voltage (rms) High Clearing Time (ms)

<1000

1000–2000

+0, –0.1 s

Voltage (rms) Low Clearing Time (ms)

<2000

2000–5000

Frequency High Clearing Time (ms)

<160

160–200

Frequency Low Clearing Time (ms)

<160

160–300000

Reconnect Delay (ms)

305000

60000–305000

n/a