Specifications

A–2

975-0320-01-01

Electrical Specifications

Input

Output

Input voltage, Maximum Power Point range

240 to 550 Vdc

Absolute maximum array open circuit voltage

600 Vdc

Maximum input current

22.0 Adc

Maximum array short circuit current

24 Adc

Reverse polarity protection

Short circuit diode

Ground fault protection

GF detection, I

DIF

> 1 A

Maximum output power

5000 W AC

Nominal output voltage

240 V

Operating range, utility voltage*

*

Factory settings can be adjusted with the approval of the utility. This
unit is provided with adjustable trip limits and may be aggregated
above 30 kW on a single Point of Common Coupling. See “Adjustable
Voltage, Frequency and Reconnection Settings” on page A–3.

211 to 264 Vac

Nominal output frequency

60 Hz

Operating range, utility frequency*

59.3 to 60.5 Hz

Startup current

0 Aac

Maximum continuous output current

21 A

Output overcurrent protection

30 A RMS

Maximum utility backfeed current

0 A

Total Harmonic Distortion

<5%

Power factor

>0.95%

Utility monitoring— islanding protection

Vac, fac as per UL 1741 (2005)

Output characteristics

Current source

Output current waveform

Sine wave