ZyXEL Communications ZyXEL Dimension ES-2108 User Manual

Page 108

Advertising
background image

ES-2108 Series User’s Guide

108

Chapter 12 Bandwidth Control

*

Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row

first to set the common settings and then make adjustments on a port-by-port basis.

Note: Changes in this row are copied to all the ports as soon as you

make them.

Active

Make sure to select this check box to activate ingress limits on a port.

Ingress Rate

Specify the maximum bandwidth allowed in Kilobits per second (Kbps) for the incoming

traffic flow on a port.
If you enter a number between 64 and 1728, the switch automatically rounds the

number down to the nearest multiple of 64.
If you enter a number between 1729 and 1999, the rate is fixed at 1792.
If you enter a number between 2000 and 103999, the switch rounds the number down

to the nearest multiple of 1000.
On a Gigabit Ethernet/ Mini-GBIC port, the switch rounds a number down to the

nearest multiple of 8000 for a number between 104000 and 1000000.

Active

Make sure to select this check box to activate egress limits on a port.

Egress Rate

Specify the maximum bandwidth allowed in Kilobits per second (Kbps) for the out-

going traffic flow on a port.
If you enter a number between 64 and 1728, the switch automatically rounds the

number down to the nearest multiple of 64.
If you enter a number between 1729 and 1999, the rate is fixed at 1792.
If you enter a number between 2000 and 103999, the switch rounds the number down

to the nearest multiple of 1000.
On a Gigabit Ethernet/ Mini-GBIC port, the switch rounds a number down to the

nearest multiple of 8000 for a number between 104000 and 1000000.

Apply

Click Apply to save your changes to the switch’s run-time memory. The switch loses

these changes if it is turned off or loses power, so use the Save link on the top

navigation panel to save your changes to the non-volatile memory when you are done

configuring.

Cancel

Click Cancel to reset the fields to your previous configuration.

Table 26 Bandwidth Control (continued)

LABEL

DESCRIPTION